GrubVetter

Redmint

2044 Fillmore St

P

Last inspected: May 8, 2024

Inspection History

May 8, 2024
Pass
P
114099Provide a 3-compartment sink with two integral metal drainboards for manually washing, rinsing, and sanitizing equipment and utensils., 114192, 113953 - An adequate, protected, pressurized, potable supply of hot water at least 120F and cold water shall be provided., 114268 - The floor finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms., 114268 - Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches., 114130, 114169 - All equipment shall be installed on castors, six (6) inch high round metal legs, or on a minimum four (4) inch high curb or pedestal with a continuously coved base at the juncture., 114130, 114169 - All new and used equipment and utensils shall be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program, e.g. NSF, ETL Sanitation, UL Sanitation, CSA Sanitation. , 114279, 114281, 114282 - At least one curbed cleaning facility or janitorial sink equipped with hot and cold water and a drain shall be provided and conveniently located., 114271 - Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms., 114192, 113953 - The water supply shall be from a water system approved by the local enforcement agency. , 114193, 114193.1, 114269 - Equipment that discharges liquid waste, e.g. food preparation sinks, dishwashing machines, steam tables, ice machines and bins, espresso machines, walk-in refrigeration units, shall have approved indirect drainage through an air gap into a floor sink or other approved receiving vessel., 114193, 114193.1, 114269 - An air gap between the water supply inlet and the flood level rim of the plumbing fixture shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch., 113953, 113953(b) - Hand sinks shall be sufficient in number and conveniently located so as to be accessible at all times., 114130, 114169 - Floor-mounted equipment that is not easily movable shall be sealed to the floor.
May 8, 2024
Pass
P
114099Provide a 3-compartment sink with two integral metal drainboards for manually washing, rinsing, and sanitizing equipment and utensils., 114192, 113953 - An adequate, protected, pressurized, potable supply of hot water at least 120F and cold water shall be provided., 114268 - The floor finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms., 114268 - Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches., 114130, 114169 - All equipment shall be installed on castors, six (6) inch high round metal legs, or on a minimum four (4) inch high curb or pedestal with a continuously coved base at the juncture., 114130, 114169 - All new and used equipment and utensils shall be certified or classified for sanitation by an American National Standards Institute (ANSI) accredited certification program, e.g. NSF, ETL Sanitation, UL Sanitation, CSA Sanitation. , 114279, 114281, 114282 - At least one curbed cleaning facility or janitorial sink equipped with hot and cold water and a drain shall be provided and conveniently located., 114271 - Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms., 114192, 113953 - The water supply shall be from a water system approved by the local enforcement agency. , 114193, 114193.1, 114269 - Equipment that discharges liquid waste, e.g. food preparation sinks, dishwashing machines, steam tables, ice machines and bins, espresso machines, walk-in refrigeration units, shall have approved indirect drainage through an air gap into a floor sink or other approved receiving vessel., 114193, 114193.1, 114269 - An air gap between the water supply inlet and the flood level rim of the plumbing fixture shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch., 113953, 113953(b) - Hand sinks shall be sufficient in number and conveniently located so as to be accessible at all times., 114130, 114169 - Floor-mounted equipment that is not easily movable shall be sealed to the floor.