Sage Brekfast
49 S Van Ness Ave 7Th Floor
P
Last inspected: November 5, 2024
Inspection History
November 5, 2024
Pass
P
114268Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches., 114130, 114169 - Submit specification sheets of proposed equipment to DPH for review and approval, prior to purchase and installation., 114193, 114193.1, 114269 - Equipment that discharges liquid waste, e.g. food preparation sinks, dishwashing machines, steam tables, ice machines and bins, espresso machines, walk-in refrigeration units, shall have approved indirect drainage through an air gap into a floor sink or other approved receiving vessel., 114153 - Equipment for cooling, e.g. ice machine, walk-in cooler/freezer, shall be sufficient in number and capacity to ensure proper food temperature control., 114193, 114193.1, 114269 - An air gap between the water supply inlet and the flood level rim of the plumbing fixture shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch., 114193, 114193.1, 114269 - Floor drains shall be installed in floors that are water-flushed for cleaning and in areas where pressure spray methods for cleaning equipment are used., 114266, 114257, 114257.1, 114259 - A food facility shall at all times be constructed, equipped, and maintained, and operated as to prevent the entrance and harborage of animals, birds, and vermin, including, but not limited to rodents and insects., 114268 - The floor finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms., 114130, 114169 - All equipment shall be installed on castors, six (6) inch high round metal legs, or on a minimum four (4) inch high curb or pedestal with a continuously coved base at the juncture., 114099 - Provide a 3-compartment sink with two integral metal drainboards for manually washing, rinsing, and sanitizing equipment and utensils., 114047, 114153 - Adequate and suitable space shall be provided for the storage of food, on approved shelving with a minimum of 6 inch clearance from the floor., 114271 - Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms., 113953, 113953(b) - Provide minimum 6 inches high side splashguard(s) with rounded corners., 114271(d) - Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed so as to facilitate cleaning., 114163 - All permanent food facilities that wash, rinse, soak, thaw, or similarly prepare foods shall be provided with a food preparation sink with a single integral drainboard. The food preparation sink shall have a minimum dimension of 18"x18"x12" (LxWxD) with an integral drainboard at least 18"x18" (LxW).
November 5, 2024
Pass
P
114268Floor surfaces shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius coving and shall extend up the wall at least 4 inches., 114130, 114169 - Submit specification sheets of proposed equipment to DPH for review and approval, prior to purchase and installation., 114193, 114193.1, 114269 - Equipment that discharges liquid waste, e.g. food preparation sinks, dishwashing machines, steam tables, ice machines and bins, espresso machines, walk-in refrigeration units, shall have approved indirect drainage through an air gap into a floor sink or other approved receiving vessel., 114153 - Equipment for cooling, e.g. ice machine, walk-in cooler/freezer, shall be sufficient in number and capacity to ensure proper food temperature control., 114193, 114193.1, 114269 - An air gap between the water supply inlet and the flood level rim of the plumbing fixture shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch., 114193, 114193.1, 114269 - Floor drains shall be installed in floors that are water-flushed for cleaning and in areas where pressure spray methods for cleaning equipment are used., 114266, 114257, 114257.1, 114259 - A food facility shall at all times be constructed, equipped, and maintained, and operated as to prevent the entrance and harborage of animals, birds, and vermin, including, but not limited to rodents and insects., 114268 - The floor finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms., 114130, 114169 - All equipment shall be installed on castors, six (6) inch high round metal legs, or on a minimum four (4) inch high curb or pedestal with a continuously coved base at the juncture., 114099 - Provide a 3-compartment sink with two integral metal drainboards for manually washing, rinsing, and sanitizing equipment and utensils., 114047, 114153 - Adequate and suitable space shall be provided for the storage of food, on approved shelving with a minimum of 6 inch clearance from the floor., 114271 - Wall and ceiling finish shall be smooth, durable, easily cleanable, and non-absorbent in all areas where there is food service or preparation, open food storage, warewashing, janitorial service, trash storage, and employee restrooms., 113953, 113953(b) - Provide minimum 6 inches high side splashguard(s) with rounded corners., 114271(d) - Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed so as to facilitate cleaning., 114163 - All permanent food facilities that wash, rinse, soak, thaw, or similarly prepare foods shall be provided with a food preparation sink with a single integral drainboard. The food preparation sink shall have a minimum dimension of 18"x18"x12" (LxWxD) with an integral drainboard at least 18"x18" (LxW).